[6104] C
PHY IC error
The PHY IC on the controller cannot
be correctly recognized.
Same as SC823-[6101]
[6105] C
PHY IC loop-back error
An error occurred during the loop-
back test for the PHY IC on the
controller.
Same as SC823-[6101]
824
[1401]
B
Self-diagnostic Error: NVRAM
The controller cannot recognize the
standard NVRAM installed or
detects that the NVRAM is defective.
Loose connection
Defective standard NVRAM
Defective controller
1. Check the standard NVRAM is firmly
inserted into the socket.
2. Replace the NVRAM.
3. Replace the controller
826
B
Self-diagnostic Error: RTC/Optional NVRAM
[1501]: Clock error
An RTC device is recognized,
and the difference between the
RTC device and the CPU
exceeds the defined limit.
No RTC device is recognized.
RTC defective
1. Replace the RTC device.
B
[15FF]: RTC not detected
The RTC device is not detected.
NVRAM without RTC installed
Backup battery discharged
1. Replace the NVRAM with another
NVRAM with an RTC device.
827 Self-diagnostic Error: RAM
SC Tables
177