CAUTION
The shaft should not come out of the shield unit.
7. To remove the fusing unit, pull out the unit and
remove one stepped screw.
8. Peel off three sheets of shielding mylar for the
mirror/lens motor fixing screws.
9. Remove the connectors for the mirror/lens motor
and mirror/lens home position sensor.
10. Put a screwdriver through the blind to loosen the
mirror/lens motor fixing screws (2 stepped screws
and one M5 screw).
CAUTION
The 1st mirror unit drops if the screw is
completely removed. Before removing the
screws for the worm gear disengage, insert a
screwdriver in the mirror unit fixing hole to hold
the unit.
11. While holding the mirror/lens motor with one hand,
remove the three screws securing the motor.
CAUTION
Lubricate the worm gear of the mirror/lens
motor with Mobil Temp. 78 every 1200 K. You
do not have to remove the motor at that time.
12. Replace the motor and reinstall it in the reverse
order.
CAUTION
• Check and be sure that the worm gear of
the mirror/lens motor is correctly engaged.
• When power is turned ON, the mirror/lens
motor starts and stops when the 1st mirror
unit activates the magnification home
position sensor.
Shielding mylar
Two stepped screws
M5 screw
Connector for
mirror/lens
motor
Connector for
magnification
home position
sensor
Mirror unit
fixing hole
1st mirror unit