SC Tables
M065/M066 3-58 SM Appendix
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
990
CTL
D
Software performance error
The software makes an unexpected operation.
Defective software
Defective controller
Software error
1. Turn the main switch off and on.
2. Reinstall the controller and/or engine main firmware.
See Note 1 at the end of the SC table.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
991
CTL
C
Software continuity error
The software has attempted to perform an unexpected operation.
However, unlike SC 990, the object of the error is continuity of the
software.
Software program error
Internal parameter incorrect, insufficient working memory.
This SC is not displayed on the operation panel (logging only).
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
992
CTL
D
Undefined error
Defective software program
An error undetectable by any other SC code occurred
Print the "Logging Data" with SP5990-004 and then check the SP7990.
If 498-Engine is found in the SP7990;
1. Check the harness connection of the temperature/humidity sensor.
2. Replace the temperature/humidity sensor.

Table of Contents