SC Tables
SM Appendix 3-59 M065/M066
Appendix:
Service Call
Conditions
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
995 D CPM setting error
-001
Defective BCU
Replacement NVRAM error
1. Input the serial number with SP5811-004, and turn the main power
switch off/on.
-002
Defective NVRAM on the controller
Defective controller
1. Install a new NVRAM, and turn off and on the main power switch
after SC995-002 has occurred.
2. Reinstall the previous NVRAM or download the information with
SP5825-001, after that turn the main power off and on.
-003
Incorrect type controller installed
Defective controller
Replace the controller with the correct type.
-004
Incorrect model controller installed.
Replace the controller with the correct model.

Table of Contents