System Service Mode
M065/M066 8-30 SM Appendix
2007
[Charge AC A: LL] DFU
Charge Roller AC Current Adjustment for LL
(Color)
Displays/sets the AC current target of the charge roller for LL environment
(Low temperature and Low humidity).
001 Environmental Target: Bk *ENG
[0 to 3000 / 710 / 10
A/step]
002 Environmental Target: C *ENG
003 Environmental Target: M *ENG
[0 to 3000 / 760 / 10
A/step]
004 Environmental Target: Y *ENG
[0 to 3000 / 750 / 10
A/step]
2008
[Charge AC A: ML] DFU
Charge Roller AC Current Adjustment for MM (Color)
Displays/sets the AC current target of the charge roller for ML environment
(Meddle temperature and Low humidity).
001 Environmental Target: Bk *ENG
[0 to 3000 / 740 / 10
A/step]
002 Environmental Target: C *ENG
003 Environmental Target: M *ENG
[0 to 3000 / 760 / 10
A/step]
004 Environmental Target: Y *ENG
[0 to 3000 / 750 / 10
A/step]
2009
[Charge AC A: MM] DFU
Charge Roller AC Current Adjustment for MM (Color)
Displays/sets the AC current target of the charge roller for MM environment
(Middle temperature and Middle humidity).
001 Environmental Target: Bk *ENG
[0 to 3000 / 790 / 10
A/step]
002 Environmental Target: C *ENG
003 Environmental Target: M *ENG
004 Environmental Target: Y *ENG
[0 to 3000 / 850 / 10
A/step]