EasyManua.ls Logo

Ricoh M065 - Page 441

Ricoh M065
790 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Service Mode
SM Appendix 8-31 M065/M066
Appendix:
SP Mode
Tables
2010
[Charge AC A: MH] DFU
Charge Roller AC Current Adjustment for MH (Color)
Displays/sets the AC current target of the charge roller for MH environment
(Middle temperature and High humidity).
001 Environmental Target: Bk *ENG
[0 to 3000 / 820 / 10
A/step]
002 Environmental Target: C *ENG
003 Environmental Target: M *ENG
[0 to 3000 / 840 / 10
A/step]
004 Environmental Target: Y *ENG
[0 to 3000 / 880 / 10
A/step]
2011
[Charge AC A: HH] DFU
Charge Roller AC Current Adjustment for HH (Color)
Displays/sets the AC current target of the charge roller for HH environment
(High temperature and High humidity).
001 Environmental Target: Bk *ENG
[0 to 3000 / 860 / 10
A/step]
002 Environmental Target: C *ENG
003 Environmental Target: M *ENG
[0 to 3000 / 840 / 10
A/step]
004 Environmental Target: Y *ENG
[0 to 3000 / 940 / 10
A/step]
2012 [Charge Output Control] DFU
001 AC Voltage *ENG
Selects the AC voltage control type.
[0 or 1 / 0 / 1 /step]
0: Process control
1: Manual control (AC voltages are
decided with SP2006.)

Table of Contents

Related product manuals