System Service Mode
M065/M066 8-32 SM Appendix
2013 [Envir. Correct:PCU]
001 Envir. Range:FC:Display *ENG
Displays the environmental condition,
which is measured in absolute
humidity.
[1 to 5 / – / 1 /step]
1: LL (LL <= 4.3 g/m
3
)
2: ML (4.3 < ML <= 11.3 g/m
3
)
3: MM (11.3 < MM <= 18.0 g/m
3
)
4: MH (18.0 < MH <= 24.0 g/m
3
)
5: HH (24.0 g/m
3
< HH)
002 Forced Setting *ENG
Selects the environmental condition
manually. DFU
[0 to 5 / 0 / 1 /step]
0: The environmental condition is
determined automatically.
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
003 Absolute Humidity: Thresh 1 *ENG
Changes the humidity threshold
between LL and ML. DFU
[0 to 100 / 4.3 / 0.01 g/m
3
/step]
004 Absolute Humidity: Thresh 2 *ENG
Changes the humidity threshold
between ML and MM. DFU
[0 to 100 / 11.3 / 0.01 g/m
3
/step]
005 Absolute Humidity: Thresh 3 *ENG
Changes the humidity threshold
between MM and MH. DFU
[0 to 100 / 18.0 / 0.01 g/m
3
/step]
006 Absolute Humidity: Thresh 4 *ENG
Changes the humidity threshold
between MH and HH. DFU
[0 to 100 / 24.0 / 0.01 g/m
3
/step]
007 Current Temp.: Display *ENG
Displays the current temperature.
[0 to 100 / 0 / 1 deg/step]
008 Relative Humidity: Display *ENG
Displays the current relative humidity.
[0 to 100 / 0 / 1%RH/step]