System Service Mode
SM Appendix 8-33 M065/M066
Appendix:
SP Mode
Tables
009 Absolute Humidity: Display *ENG
Displays the absolute humidity.
[0 to 100 / 0 / 0.01 g/m
3
/step]
010 Envir. Range:Bk:Display *ENG
Displays the previous environmental
condition, which is measured in
absolute humidity.
[1 to 5 / – / 1 /step]
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
011 Previous Temp.: Display *ENG
Displays the previous temperature.
[0 to 100 / 0 / 1 deg/step]
012 Relative Humidity: Display *ENG
Displays the previous relative
humidity.
[0 to 100 / 0 / 1%RH/step]
013 Absolute Humidity: Display *ENG
Displays the previous absolute
humidity.
[0 to 100 / 0 / 0.01 g/m
3
/step]
2014 [Charge AC Control: Setting] DFU
001 Practice Interval: Power ON *ENG
[0 to 2000 / 500 / 1 page/step]
002 Practice Interval: Printing *ENG
003 Judge Interval *ENG
[0 to 500 / 10 / 1 page/step]
004 Temp Condition *ENG
[0 to 99 / 25 / 1 deg/step]
005 Relative Humidity Condition *ENG
[0 to 99 / 50 / 1 %RH/step]
006 Absolute Humidity Condition *ENG
[0 to 99 / 12 / 1 g/m
3
/step]
007 Temp Change: Thresh M *ENG
[0 to 99 / 10 / 1 deg/step]
008 RH Change: Thresh M *ENG
[0 to 99 / 50 / 1 %RH/step]
009 AH Change: Thresh M *ENG
[0 to 99 / 6 / 1 g/m
3
/step]
010 Temp Change: Thresh S *ENG
[0 to 20 / 1 / 0.1 deg/step]
011 RH Change: Thresh S *ENG
[0 to 50 / 5 / 1 %RH/step]
012 AH Change: Thresh S *ENG
[0 to 20 / 1 / 0.1 g/m
3
/step]