System Service Mode
SM Appendix 8-189 M065/M066
Appendix:
SP Mode
Tables
3223
[Vtref U/L-Limit Set] DFU
Adjusts the lower or upper limit value of Vtref for each color.
001 Lower: Bk *ENG
[0 to 5 / 2 / 0.01 V/step]
002 Lower: C *ENG
003 Lower: M *ENG
004 Lower: Y *ENG
005 Upper: Bk *ENG
[0 to 5 / 4 / 0.01 V/step]
006 Upper: C *ENG
007 Upper: M *ENG
008 Upper: Y *ENG
009 Initial TC *ENG
Adjusts the initial toner concentration.
[1 to 15 / 8 / 0.1 wt%/step]
010 Upper: TC *ENG
Adjusts the upper limit of the toner
concentration.
[1 to 15 / 10.5 / 0.1 wt%/step]
011 Lower: TC *ENG
Adjusts the lower limit of the toner
concentration.
[1 to 15 / 4 / 0.1 wt%/step]
012 Upper Sensitivity *ENG
Adjusts the upper limit of the TD sensor
sensitivity.
[0.2 to 0.5 / 0.44 / 0.001 V/wt% /step]
013 Lower Sensitivity *ENG
Adjusts the lower limit of the TD sensor
sensitivity.
[0.2 to 0.5 / 0.209 / 0.001 V/wt% /step]
014 TD Thresh H/M *ENG
[1 to 10 / 4 / 0.1 wt%/step]
015 TD Thresh M/L *ENG