System Service Mode
SM Appendix 8-195 M065/M066
Appendix:
SP Mode
Tables
225 PIX:COR:Y *ENG
226 SEL:PIX:AVE *ENG
[1 to 5 / 2 / 1 /step]
240 PID:I:LIM:Std *ENG
[0 to 1 / 0.154 / 0.001 /step]
241 PID:I:LIM:LowSpd *ENG
[0 to 1 / 0.05 / 0.001 /step]
242 PID:I:STD to Low *ENG
[0 to 5 / 0.33 / 0.01 /step]
243 PID:I:Low to STD *ENG
[0 to 5 / 3.06 / 0.01 /step]
244 PID:I:LIM:MidSpd *ENG
[0 to 1 / 0.108 / 0.001 /step]
245 PID:I:STD to MID *ENG
[0 to 5 / 0.7 / 0.01 /step]
246 PID:I:MID to STD *ENG
[0 to 5 / 1.43 / 0.01 /step]
247 PID:I:MID to Low *ENG
[0 to 5 / 0.47 / 0.01 /step]
248 PID:I:Low to MID *ENG
[0 to 5 / 2.14 / 0.01 /step]
3231
[Toner Supply: Setting] DFU
Adjusts the coefficient of the toner supply time for each color.
001 Conversion Coeff.:Bk *ENG
[0.5 to 9.99 / 2.18 / 0.01 /step]
002 Conversion Coeff.:C *ENG
003 Conversion Coeff.:M *ENG
[0.5 to 9.99 / 2.24 / 0.01 /step]
004 Conversion Coeff.:Y *ENG
[0.5 to 9.99 / 2.18 / 0.01 /step]