System Service Mode
M065/M066 8-204 SM Appendix
3311
[ID Sn Detection Value]
Displays the ID sensor (regular) offset voltage for Vsg adjustments.
001 Voffset reg: Bk *ENG
[0 to 5 / 0 / 0.01 V/step]
002 Voffset reg: C *ENG
[0 to 5.5 / 0 / 0.01 V/step]
003 Voffset reg: M *ENG
004 Voffset reg: Y *ENG
005-007 Displays the ID sensor (diffusion) offset voltage for Vsg adjustments.
005 Voffset dif: C *ENG
[0 to 5.5 / 0 / 0.01 V/step]
006 Voffset dif: M *ENG
007 Voffset dif: Y *ENG
008-010 Displays the ID sensor offset voltage for Vsg adjustments.
008 Voffset TM (Front) *ENG
[0 to 5.5 / 0 / 0.01 V/step]
009 Voffset TM (Center) *ENG
010 Voffset TM (Rear) *ENG
3321 [Vsg Adjust: Exe.]
010 P/TM Sensor All -
Execute the ID sensor initialization setting
for all sensors