Printer Service Mode
M065/M066 8-354 SM Appendix
1001 Bit Switch
009 Bit Switch 9 0 1
bit 0
PDL Auto Detection timeout of jobs
submitted via USB or Parallel Port (IEEE
1284).
0: Disable
(Immediately)
1: Enable
(10 seconds)
To be used if PDL auto-detection fails. A failure of PDL auto-detection does
not necessarily mean that the job cannot be printed. This bit switch tells the
device whether to time-out immediately (default) upon failure or to wait 10
seconds.
bit 1
to 3
DFU - -
bit 4
Timing of the PJL Status Readback (JOB
END) when printing multiple collated copies
Disabled Enabled
This bitsw determines the timing of the PJL USTATUS JOB END sent when
multiple collated copies are being printed.
0 (default): JOB END is sent by the device to the client after the first copy
has completed printing. This causes the page counter to be incremented
after the first copy and then again at the end of the job.
1: JOB END is sent by the device to the client after the last copy has
finished printing. This causes the page counter to be incremented at the end
of each job.
bit 5
to 7
DFU - -
1003 [Clear Setting]
1003 001 Initialize System
Initializes settings in the System menu of the
user mode.
1003 003 Delete Program DFU
1004 [Print Summary]
1004 001 Service Summary
Prints the service summary sheet (a
summary of all the controller settings).
1005 [Display Version]
1005 001 Printer Version
Displays the version of the controller
firmware.
⇒
Rev. 03/16