Thresh *ENG [60 to 160 / 140 / 1 deg / step]
Adjusts the threshold temperature for
the reload mode change from the
forced reload mode to normal reload
control.
1-103-004
Forced ReloadTime *ENG [5.0 to 20.0 / 23.0 / 0.1 sec / step]
Adjusts the time for the forced reload
mode (no fusing idling).
1105 [Fusing Temp Adj]
Adjusts the target fusing temperature. "Center" indicates the center of the
roller; "End" indicates the front and rear ends.
(Paper Type, Fusing Control Mode) Plain 1/2, Middle Thick, Thick 1/2
1-105-001 Center:Plain1 *ENG [160 to 200 / 170 / 1 deg / step]
1-105-003 Center:Plain2 *ENG [160 to 200 / 175 / 1 deg / step]
1-105-005 Center:M-Thick *ENG [160 to 200 / 175 / 1 deg / step]
1-105-007 Center:Thick *ENG [0 to 40 / 15 / 1 deg / step]
Adjusts the additional temperature for
the thick paper. This value is added
to the temperature for the plain 1
(SP1-105-001).
1-105-008 Center:Thick2 *ENG [0 to 40 / 25 / 1 deg / step]
Adjusts the additional temperature for
the thick paper 2. This value is added
to the temperature for the plain 1
(SP1-105-001).
1-105-009 Center Minus:Thin *ENG [0 to 20 / 10 / 1 deg / step]
Adjusts the subtract temperature for
the thin paper. This value is
subtracted from the temperature for
the plain 1 (SP1-105-001).