1-105-011 Low Power *ENG [0 to 150/ 105 / 1 deg / step]
Adjusts the standby temperature for
the low power mode.
1-105-012 Wait Temp: Center *ENG [160 to 190/ 175 / 1 deg / step]
Adjusts the standby temperature for
the normal power mode.
1-105-013 Print Ready *ENG [160 to 190/ 175 / 1 deg / step]
Adjusts the print ready temperature
for the normal power mode.
020 to 025 Turns on or off the paper waiting control for each paper type.
Thin, Plain 1/2, Middle Thick, Thick 1/2
1-105-020 Reg. Wait:Thin *ENG [0 or 1 / 1 / 1 / step]
0: Off, 1: On
1-105-021 Reg. Wait:Plain1 *ENG [0 or 1 / 1 / 1 / step]
0: Off, 1: On
1-105-022 Reg. Wait:Plain2 *ENG [0 or 1 / 1 / 1 / step]
0: Off, 1: On
1-105-023 Reg. Wait:M-Thick *ENG [0 or 1 / 1 / 1 / step]
0: Off, 1: On
1-105-024 Reg. Wait:Thick *ENG [0 or 1 / 1 / 1 / step]
0: Off, 1: On
1-105-025 Reg. Wait:Thick2 *ENG [0 or 1 / 1 / 1 / step]
0: Off, 1: On
026 to 037 Adjusts the lower or upper limit temperature against the actual target
temperarure of the fusing unit for the paper waiting control. These are
activated only if the setting of SP1-105-020 to -025 is turned on.
1-105-026 Wait:Lower:Thin *ENG [0 to 60 / 30 / 1 deg / step]
1-105-027 Wait:Lower:Plain1 *ENG [0 to 60 / 30 / 1 deg / step]
1-105-028 Wait:Lower:Plain2 *ENG [0 to 60 / 30 / 1 deg / step]
1-105-029 Wait:Lower:MThick *ENG [0 to 60 / 10 / 1 deg / step]
1-105-030 Wait:Lower:Thick *ENG [0 to 60 / 10 / 1 deg / step]