Engine SP Mode
SM 5-8 D245/D246/D247
1-105-031 Wait:Lower:Thick2 *ENG [0 to 60 / 10 / 1 deg / step]
1-105-032 Wait:Upper:Thin *ENG [0 to 60 / 40 / 1 deg / step]
1-105-033 Wait:Upper:Plain1 *ENG [0 to 60 / 40 / 1 deg / step]
1-105-034 Wait:Upper:Plain2 *ENG [0 to 60 / 40 / 1 deg / step]
1-105-035 Wait:Upper:MThick *ENG [0 to 60 / 40 / 1 deg / step]
1-105-036 Wait:Upper:Thick *ENG [0 to 60 / 40 / 1 deg / step]
1-105-037 Wait:Upper:Thick2 *ENG [0 to 60 / 40 / 1 deg / step]
1-105-038 Regist Wait Time *ENG [0 to 120 / 120 / 1 sec / step]
1-105-040 Low-V:Wait:Center *ENG [0 to 100/ 10 / 1 deg / step]
Adjusts the lower limit temperature
for the center thermistor of the fusing
unit.
1-105-041 Low-V:Wait:End *ENG [0 to 100/ 50 / 1 deg / step]
Adjusts the lower limit temperature
for the end thermistor of the fusing
unit.
1-105-043 Low-V:Wait Time *ENG [0 to 300/ 60 / 1 sec / step]
Adjusts the waiting time for the
recovery to the lower limit
temperature of the fusing unit.
If the temperature of the fusing unit
does not reach the lower limit
temperature for the specified time in
this SP, the machine stops paper
feeding, and then isses SC549-02.
1-105-050 Duplex Correction *ENG [0 to 1 / 0 / 1 / step]
1-105-061 High Temp Corr. *ENG [0 to 40 / 5 / 1 deg / step]
Adjusts the subtracted temperature
against the CPM down temperature
3.
1106 [Fusing Temp Disp]