Engine SP Mode
SM 5-9 D245/D246/D247
Maintenance
Displays the current temperature of the heating roller and ambient
temperature in the machine.
1-106-001
Roller Center ENG [-20 to 250 / 0 / 1 deg / step]
1-106-003
MachineTemp PowOn ENG [-20 to 250 / 0 / 1 deg / step]
1107 [Env. Correction]
Adjusts the settings related to the environmental correction in the low
temperature condition.
1-107-001
Thresh:S1 *ENG [0 to 50/ 17 / 1 deg / step]
Adjusts the threshold temperature for
the low temperature condition.
1-107-002
Thresh:delta t *ENG [0 to 50/ 0 / 1 deg / step]
Adjusts the additional temperature to
the threshold temperature for the low
temperature condition.
-003 to
Adjusts the correction temperature to the threshold temperature for each
paper type
1-107-003
Low:thin *ENG [0 to 30/ 0 / 1 deg / step]
1-107-004
Low:Plain1 *ENG [0 to 30/ 0 / 1 deg / step]
1-107-005
Low:Plain2 *ENG [0 to 30/ 0 / 1 deg / step]
1-107-006
Low:M-Thick *ENG [0 to 30/ 0 / 1 deg / step]
1-107-007
Low:Thick *ENG [0 to 30/ 0 / 1 deg / step]
1-107-008
Low:Thick2 *ENG [0 to 30/ 0 / 1 deg / step]
1108 [CNTL Period Adj]
Adjusts the fusing control interval for each mode.
1-108-001
Warming-Up *ENG [100 to 3000 / 1000 / 100 msec / step]
1-108-002
Print *ENG [100 to 3000 / 1000 / 100 msec / step]
1-108-003
Wait *ENG [100 to 3000 / 1000 / 100 msec / step]