Engine SP Mode
SM 5-10 D245/D246/D247
1-108-004
Print Start *ENG [100 to 3000 / 200 / 100 msec / step]
1-108-005
Print Start Time *ENG [0 to 999 / 5 / 1 sec / step]
1109 [Fusing Rev. Adj]
Adjusts the time for the fusing temperature control.
1-109-001
Before Print Time *ENG [0 to 120 / 7 / 1 sec / step]
Adjusts the idling time for the fusing
unit before printing.
1-109-002
Pre Rev. Time *ENG [0 to 120 / 120 / 1 sec / step]
1-109-003
Low-V PrePrt Time *ENG [0 to 120 / 0 / 1 sec / step]
Adjusts the idling time for the fusing
unit in the low voltage mode.
1112 [Image Temp Corr]
These SPs are used for the fusing temperature control for variable job
images. This control saves the power consumption when the machine
copies or prints a job text image in black and white mode.
1-112-001
Temp.:Normal:Lv1 *ENG [-25 to 10 / 0 / 1 deg / step]
1-112-002
Temp.:Normal:Lv2 *ENG [-25 to 10 / 0 / 1 deg / step]
1124 [CPM Down Setting]
Sets the temperature differential used to calculate CPM down for low and
high temperatures. Also, sets the interval for temperature checks for CPM
down.
1-124-001
Low:Down Tem p. *ENG [-50 to 0 / -25 / 1 deg / step]
1-124-002
Low:Up Temp. *ENG [-50 to 0 / -5 / 1 deg / step]
1-124-003
Low :1st CPM *ENG [10 to 100 / 80 / 5% / step]
1-124-004
Low :2nd CPM *ENG [10 to 100 / 60 / 5% / step]
1-124-005
Low :3rd CPM *ENG [10 to 100 / 40 / 5% / step]

Table of Contents