SC Code Descriptions
SM 6-22 D245/D246/D247
SC No. Level Error Name/Error Condition/Major Cause/Solution
542-01 A Reload failure: Thermistor deformation
The temperature of 9°C or lower is detected five times
consecutively for three seconds.
Measurement begins 15 seconds after the heater is turned
on.
Measurement interval: 0.1 sec.
If the reload temperature is reached during measuring, the
measurement is cancelled.
Thermistor deformed
Thermistor out of position
Out of guaranteed input voltage
Replace the thermistor (center).
Clear this SC by executing SP5-810-001.
SC No. Level Error Name/Error Condition/Major Cause/Solution
542-03 A Reload failure: Heater damage
Normal (no pre-rotation):
The reload temperature is not reached for 35 seconds after
heater control starts.
Pre-rotation:
The reload temperature is not reached for 90 seconds after
heater control starts.
Heater damaged
After over-heat prevention
Replace the heater.
Clear this SC by executing SP5-810-001.