SC No. Level Error Name/Error Condition/Major Cause/Solution
542-04 B Reload failure: Low voltage and thermistor deformation
An error is detected only when the input voltage at power-on is
low.
The temperature of 7°C or lower is detected five times
consecutively for 3 seconds.
Measurement begins 15 seconds after the heater is turned
on.
Measurement interval: 0.1 sec.
If the reload temperature is reached during measuring, the
measurement is cancelled.
Thermistor deformed
Thermistor out of position
Out of guaranteed input voltage
After over-heat prevention
Replace the thermistor (center).
SC No. Level Error Name/Error Condition/Major Cause/Solution
542-06 B Reload failure: Low voltage and heater deformation
An error is detected only when the input voltage at power-on is
low.
Normal (no pre-rotation):
The reload temperature is not reached for 90 seconds after
heater control starts.
Pre-rotation:
The reload temperature is not reached for 285 seconds after
heater control starts.
Heater damaged
After over-heat prevention
Replace the heater.