SC Code Descriptions
SM 6-27 D245/D246/D247
Troubleshooting
SC No. Level Error Name/Error Condition/Major Cause/Solution
547-03 B Zero cross error (low-frequency error)
When low frequency is detected once, the SC557 is determined.
When low frequency is detected twice or more, this SC is
issued.
Fusing relay defective (contact soldering, contact open)
Drive circuit of the fusing relay defective
PSU fuse (24 VS) damaged
Frequency instability of input power line
Replace the fusing relay.
Replace the fuse of the PSU.
SC No. Level Error Name/Error Condition/Major Cause/Solution
549-01 B Temperature lowering detection
When the thermistor (center) detects 75°C lower than the target
temperature of each paper type for 60 seconds continuously
after the registration roller has started to rotate, this SC is
issued.
Heater damaged during paper feeding
Heater not connected correctly.
Reconnect the heater.
Replace the heater.