SC Code Descriptions
SM 6-28 D245/D246/D247
SC No. Level Error Name/Error Condition/Major Cause/Solution
549-02 B Temperature lowering detection: Low voltage
When fusing temperature does not reach the target temperature
for each paper type for the specified time with SP1-105-043
(default: 60 sec) after the fusing pre-rotation due to the low
voltage, this SC is issued.
Heater damaged during paper feeding
Loose connectors
Lowering the input voltage
Reconnect the heater.
Replace the heater.
SC No. Level Error Name/Error Condition/Major Cause/Solution
549-03 B Temperature lowering detection: Low voltage
When fusing temperature does not reach the target temperature
for each paper type for the specified time with SP1-124-104
(default: 30 sec) after the machine has entered the CPM down
level 3 in the low voltage operation mode, this SC is issued.
Heater damaged during paper feeding
Loose connectors
Lowering the input voltage
Reconnect the heater.
Replace the heater.