RIGOL Chapter 2 Command System
2-24 DP800 Programming Guide
:MMEMory:STORe
Syntax :MMEMory:STORe <file_name>
Description Save the file with the specified filename under the current operation directory.
Parameter
Name Type Range Default
<file_name>
ASCII character
string
Filename of the file to be saved,
including Chinese characters, English
characters or numbers
None
Explanation With this command, you can save the state file (RSF), timer file (RTF) and delay file
(RDF).
If the current operation directory already contains a file with the same filename,
this command will overwrite the original file directly.
Example :MMEM:STORe STB.RSF /*Save the current instrument state under the current
operation directory with the name STB.RSF*/

Table of Contents

Other manuals for Rigol DP832

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP832 and is the answer not in the manual?

Rigol DP832 Specifications

General IconGeneral
Number of Outputs3
Output Voltage Range CH1/CH20-30V
Output Voltage Range CH30-5V
Output Current Range CH1/CH20-3A
Output Current Range CH30-3A
Total Power195 W
Power per Channel CH1/CH290 W
Power per Channel CH315 W
Voltage Resolution1 mV
Current Resolution1 mA
InterfacesUSB, RS232
Display3.5 inch TFT LCD