Serial Interface
Vel Disp Build Upper
Frequency weighting of building Vel and Disp upper
Setting upper limit of frequency range for Building damage Vel. and Disp.
Setting command Vel
Disp Build Upper, p1
Parameter p1= “80Hz”
p1= “100Hz
p1=250Hz
p1=Sensor Dependent
Request command Vel
Disp Build Upper?
Response data d1
Returned value Same as for setting command
Vel Human Lower
Frequency weighting of human Vel lower
Setting lower limit of frequency range for Human exposure Vel.
Setting command Vel Human Lower, p1
Parameter p1= “0.5Hz”
p1= “1Hz
p1= “4Hz
Request command Vel
Human Lower?
Response data d1
Returned value Same as for setting command