28 WisDom User Manual
¾ To unset using a duress code:
1)
If outside the premises, open an "entry" door. The
WisDom beeps, indicating that the Entry Delay time
period has begun. The following message will be heard
"System is unsetting. Please enter your code"
2)
Enter your duress code and press
.All partitions
assigned to the code are unset and a silent alarm is
sent to the Alarm Receiving Center.
Unsetting After an Alarm
When silencing an alarm the system goes into unset state.
¾ To unset an alarm using a user code:
1)
If outside the premises, open an "entry" door. The
WisDom beeps, indicating that the Entry Delay period has
begun.
2)
Observe the system LEDs. If the SET LED is flashing
and the display shows the distributed zone, an alarm
has occurred in the system.
3)
Enter your user code and press
. The following
message will be heard:
"System / [Partition X] is unset "
The SET LED will flash and the display will show the
alarmed zones for the alarm memory period of about 60
seconds. Scroll through the list of alarm zones. To exit the
Alarm Memory mode before the timeout has expired,
press
.
4)
Proceed to “Resetting after an Alarm”
NOTES:
It is recommended to leave the premises. Only after police investigation should
you consider that the burglar is no longer in your premises and you can re-enter.
In special cases (if programmed so during installation), setting the system after
an alarm requires an Engineer code. On the LCD, a “Call Engineer” message
will appear (see Resetting after an Alarm in the next page).