EasyManua.ls Logo

Rohde & Schwarz FSW Series - 11.4.2 Configuring the Input

Rohde & Schwarz FSW Series
371 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
181User Manual 1173.9240.02 ─ 17
Manual operation: See "Load Standard" on page 53
[SENSe:]ADEMod:PRESet:RESTore
This command restores the default configurations of predefined Analog Demodulation
standards.
Note that the command will overwrite customized standards that have the same name
as predefined standards.
Usage: Event
Manual operation: See "Restore Standard Files" on page 53
[SENSe:]ADEMod:PRESet:STORe <Standard>
This command saves the current Analog Demodualtion measurement configuration.
Standard definitions are stored in an xml file. The default directory for Analog Demodu-
altion standards is C:\r_s\instr\user\predefined\AdemodPredefined.
Parameters:
<Standard> String containing the file name.
You can save the file in a subdirectory of the directory men-
tioned above. In that case, you have to include the relative path
to the file.
Manual operation: See "Save Standard" on page 53
11.4.2 Configuring the Input
RF Input................................................................................................................ 181
Using External Mixers........................................................................................... 184
Configuring Input via the Analog Baseband Interface (R&S FSW-B71)............... 198
Configuring Digital I/Q Input and Output............................................................... 202
Setting up Probes..................................................................................................206
Working with Power Sensors................................................................................ 208
External Generator Control................................................................................... 219
11.4.2.1 RF Input
INPut:ATTenuation:PROTection:RESet............................................................................182
INPut:CONNector...........................................................................................................182
INPut:COUPling.............................................................................................................182
INPut:FILTer:HPASs[:STATe]..........................................................................................183
INPut:FILTer:YIG[:STATe].............................................................................................. 183
INPut:IMPedance...........................................................................................................183
INPut:SELect.................................................................................................................184
Configuring the Measurement