Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
300User Manual 1173.9240.02 ─ 17
● Working with Markers Remotely........................................................................... 300
● Defining Limit Checks........................................................................................... 322
● Zooming into the Display.......................................................................................334
● Configuring an Analysis Interval and Line (MSRA mode only)............................. 336
● Configuring an Analysis Interval and Line (MSRT mode only)..............................338
11.8.1 Working with Markers Remotely
In the Analog Demodulation application, up to 16 markers or delta markers can be acti-
vated for each window simultaneously.
More details are described for manual operation in chapter 6.5, "Marker Function Con-
figuration", on page 142.
● Setting Up Individual Markers............................................................................... 300
● General Marker Settings....................................................................................... 306
● Marker Search Settings.........................................................................................308
● Positioning the Marker.......................................................................................... 308
● Configuring Special Marker Functions.................................................................. 312
11.8.1.1 Setting Up Individual Markers
The following commands define the position of markers in the diagram.
CALCulate<n>:MARKer<m>:AOFF..................................................................................300
CALCulate<n>:MARKer<m1>:LINK:TO:MARKer<m2>.......................................................301
CALCulate<n>:MARKer<m>[:STATe]...............................................................................301
CALCulate<n>:MARKer<m>:TRACe................................................................................301
CALCulate<n>:MARKer<m>:X........................................................................................ 301
CALCulate<n>:MARKer<m>:Y?.......................................................................................302
CALCulate<n>:DELTamarker:AOFF................................................................................ 303
CALCulate<n>:DELTamarker<m>:LINK........................................................................... 303
CALCulate<n>:DELTamarker<m1>:LINK:TO:MARKer<m2>...............................................303
CALCulate<n>:DELTamarker:MODE............................................................................... 303
CALCulate<n>:DELTamarker<m>:MREF......................................................................... 304
CALCulate<n>:DELTamarker<m>[:STATe].......................................................................304
CALCulate<n>:DELTamarker<m>:TRACe........................................................................304
CALCulate<n>:DELTamarker<m>:X................................................................................ 305
CALCulate<n>:DELTamarker<m>:X:RELative?.................................................................305
CALCulate<n>:DELTamarker<m>:Y?...............................................................................305
CALCulate<n>:MARKer<m>:AOFF
This command turns all markers off.
Example:
CALC:MARK:AOFF
Switches off all markers.
Usage: Event
Manual operation: See "All Markers Off" on page 137