Deleting Musical Data (Delete Event)
1. In the Microscope display, rotate the
[VALUE] dial to select the musical data that
you wish to delete.
2. Press NUMBER [2] (DELETE).
The confirmation page will appear.
fig.9-72 (#MC fig.10-73)
3. Press [ENTER].
The musical data will be deleted.
Inserting Musical Data (Insert Event)
1. In the Microscope display, rotate the
[VALUE] dial to move to the position where
you wish to insert musical data.
2. Press NUMBER [3] (INSERT).
The Insert Event page will appear, and the following
display will appear.
fig.9-73 (#MC fig.10-74)
3.
Use [INC] [DEC] or the [VALUE] dial to select
the type of musical data that will be inserted.
Range:
When you are viewing a part 1–R in the Microscope
Note: Note
PC: Program change
CC: Control change
Pch Bend: Pitch bend
P-AFT: Polyphonic aftertouch
ChAfter: Channel aftertouch
When you are viewing a MUTE CTRL part in the
Microscope
Sys-Ex System exclusive
Tempo: Tempo
Mute: Mute
4. Press [ENTER].
A message with basic settings for the selected type of
musical data will appear.
fig.9-74 (#MC fig.10-75)
5. Press PAGE [<] [>] to move the cursor to the
location that you wish to modify.
6. Use [INC] [DEC] or the [VALUE] dial to modi-
fy the value.
7. Press [ENTER] to finalize the settings.
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
Using the keyboard and knobs to directly
insert musical data
To input a note number, simply press a note to input
the corresponding note number.
To input a control change, rotate a patch parameter
knob, and the controller number and value for that
knob will be input.
fig.9-68 (#MC fig.10-77)
If you rotate a knob that is different than the controller
number which is displayed, the controller number
which had been input at that location will be replaced.
fig.9-68-1
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
If you select “Sys-Ex” (System Exclusive), the follow-
ing message will appear. In the same way as for the
Change Event operation, use [INC] [DEC] or the
[VALUE] dial and [ENTER] to successively enter hexa-
decimal data.
fig.9-75 (#MC fig.10-76)
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
2
SD
DELETE
3
HH
INSERT
CUTOFF
CUTOFF
RESONANCE
Chapter 9. Editing Patterns
150
9

Table of Contents