❍ Bank Select (Controller number 0,32)
status 2nd byte 3rd byte
BnH 00H mmH
BnH 20H llH
mm,ll=Bank number: 00 00H - 7F 7FH (bank.1 - bank.16384)
* This message is not transmitted if Tx Program Change Switch parameter or Tx Bank
Select Switch parameter is OFF.
* For the Bank Select that corresponds to each Patch, refer to section 1.
❍ Modulation (Controller number 1)
status 2nd byte 3rd byte
BnH 01H vvH
❍ Portamento Time (Controller number 5)
status 2nd byte 3rd byte
BnH 05H vvH
❍ Volume (Controller number 7)
status 2nd byte 3rd byte
BnH 07H vvH
❍ Panpot (Controller number 10)
status 2nd byte 3rd byte
BnH 0AH vvH
❍ Expression (Controller number 11)
status 2nd byte 3rd byte
BnH 0BH vvH
❍ General purpose Controller1, 3, 4 (Controller number 16, 18, 19)
status 2nd byte 3rd byte
BnH 10H,12H,13H vvH
❍ Hold 1 (Controller number 64)
status 2nd byte 3rd byte
BnH 40H xxH
❍ Portamento (Controller number 65)
status 2nd byte 3rd byte
BnH 41H xxH
❍ Sostenuto (Controller number 66)
status 2nd byte 3rd byte
BnH 42H xxH
❍ Soft (Controller number 67)
status 2nd byte 3rd byte
BnH 43H xxH
❍ Hold 2 (Controller number 69)
status 2nd byte 3rd byte
BnH 45H xxH
❍ Sound Controller2–6,8 (Controller number 71–75, 77)
status 2nd byte 3rd byte
BnH 47H-4BH,4DH vvH
❍ General purpose Controller5–8 (Controller number 80–83)
status 2nd byte 3rd byte
BnH 50H-53H vvH
❍ Portamento control (Controller number 84)
status 2nd byte 3rd byte
BnH 54H kkH
❍ Effect 1 (Controller number 91)
status 2nd byte 3rd byte
BnH 5BH vvH
❍ Effect 4 (Controller number 91)
status 2nd byte 3rd byte
BnH 5EH vvH
● Program Change
status 2nd byte
CnH ppH
pp=Program number: 00H - 7FH (prog.1 - prog.128)
* This message is not transmitted when the Tx Program Change Switch parameter is
OFF.
● Channel Aftertouch
status 2nd byte
DnH vvH
● Pitch Bend Change
status 2nd byte 3rd byte
EnH llH mmH
mm,ll=Pitch Bend value: 00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191)
■ System Realtime messages
● Active Sensing
status
FEH
* Transmitted at intervals of approximately 250ms.
* Not transmitted if the Tx Active Sensing Switch parameter is OFF.
■ System Exclusive messages
● Universal Non-realtime System Exclusive Messages
❍ Inquiry Reply
Status Data byte Status
F0H 7EH, dev, 06H, 02H, 41H, 0BH, 01H, 01H, 00H, 00H, 03H, 00H, 00H F7H
Byte Explanation
F0H Exclusive status
7EH ID number (universal non-realtime message)
dev Device ID (dev:10H(17)-1FH(32))
06H Sub ID#1 (General Information)
02H Sub ID#2 (Inquiry Reply)
41H ID number (Roland)
0BH 01H Device family code
01H 00H Device family number code
00H 03H 00H 00H Software revision level
F7H EOX (End of Exclusive)
* When Inquiry Request is received, Inquiry Reply message will be transmitted.
240