126
Messages and Error Messages
This section lists the messages (error messages) that the TD-20X produces and explains the meaning of each message,
giving you the appropriate action to take.
fig.99-001-error-accept.eps_70
When an indication of “ACCEPT” is shown above the
[F5] button as in the figure, pressing that button will
close the message window.
Error Messages
Message
Meaning Action
Backup Battery Low!
The internal backup battery of the TD-20X (a battery that
maintains data in the user memory) has run down.
Contact your dealer or a nearby Roland service center to
have the battery replaced.
System Initialize
Data in the TD-20X’s memory may be corrupted. The TD-
20X’s internal backup battery (the battery used for saving
User memory data) is fully drained; internal data has been
lost.
Contact your dealer or a nearby Roland service center to
have the battery replaced. Follow the messages appearing
on the screen to carry out Factory Reset (p. 114); you will
then be able to use the unit temporarily.
MIDI Communication
Error!
It is possible that the power has been turned off for the MIDI
device connected to the TD-20X’s MIDI IN connector.
Check the power of the connected MIDI device.
System Error! A problem has occurred with the internal system. Contact your dealer or a nearby Roland service center.
Measure Maximum!
The maximum number of measures that can be recorded to
one pattern has been exceeded; no further recording or
editing that adds measures can be carried out.
Delete unneeded measures from the pattern being
recorded or edited (p. 88).
Step Maximum!
The maximum number of steps that can be recorded to one
chain has been exceeded; no further editing that adds steps
can be carried out.
Delete unneeded steps from the chain being edited (p. 43).
Data Overload!
Pattern contained an excessive amount of data, and as a
result could not be output successfully from MIDI OUT.
Try eliminating a part that has too much data.
Not Enough Memory!
Pattern recording or editing could not be carried out
because there was not enough internal memory.
Try deleting patterns that are no longer needed (p. 88).
No Card! No card is in the CompactFlash card slot. Insert a CompactFlash card.
No Space! There are no empty space on the CompactFlash card. Delete unneeded data (p. 94).
No Data! No data you request on the CompactFlash card.
Unsupported!
A card the size of which is not supported by TD-20X has
been inserted.
Cards supported by TD-20X are 3.3 V CompactFlash cards
with the capacity of 16 MB to 4 GB. Check the card.
Unformatted!
A card the format of which is not supported by TD-20X has
been inserted.
Format the card (p. 94).
Card Damaged! The data stored on the card has been corrupted. Format the card (p. 94).
BULK DUMP
Checksum Error!
The checksum value of a system exclusive message was
incorrect.
Correct the checksum value.
BULK DUMP
Receive Address Error!
The receive address of a system exclusive message was
incorrect.
Correct the receive address.
BULK DUMP
Receive Data Error!
A MIDI message was received incorrectly.
If the same error message is displayed repeatedly, there is
a problem with the MIDI messages that are being
transmitted to the TD-20X.
BULK DUMP
Receive Time Out!
The interval in receiving system exclusive messages were
too long.
Make the interval of the data shorter.
TD-20X_e.book 126 ページ 2009年6月8日 月曜日 午後3時50分