42
Reference Manual
00809-0100-4803, Rev GA
Configuration
September 2017
Configuration
Time conversion example
To find the Base per Custom relationship for a custom unit of standard cubic feet per hour (scf/h) and a
base unit of standard cubic feet per minute (StdCuft/min), input the following:
Custom Unit = scf/h
Base Unit = StdCuft/min
Because:
1 h (Hour) = 60 min (Minutes)
Then:
1 scf/h = ⫻ = 0.016667 StdCuft/min
1 scf/h = 0.016667 StdCuft/min
Therefore:
Base per Custom = = = 0.016667
Figure 2-29. Flow Rate Custom Units - Time Conversion Example
1h⋅
60 min⋅
---------------------
Number of Base Units
1xCustomxUnit
----------------------------------------------------------------------
0.016667 StdCuft min⁄⋅
1scfh⁄⋅
----------------------------------------------------------------- -