BRP-Rotax
MAINTENANCE MANUAL
Points of Inspection
Interval Operating hours Chapter
Reference
Signa-
ture
* no periodic maintenance (require-
ment after the first 25 hours of
operation)
25* 50 100 200 600 1000
3) Spark plug
Check that spark plug connectors fit
tightly on the spark plugs. Minimum
pull-off force is 30 N (7 lb).
X X X 12–20–00
Inspection of
spark plugs
Remove all spark plugs and check for
spark plug defects (deposits, melt-
ing,...). Check if GENUINE-ROTAX®-
spark plugs are used.
X X X X X 12–20–00
Remove the
spark plugs
Replacing spark plugs.
(2
use of leaded fuel more than 30% of
operation
X
(2
X X X 12–20–00
Installation of
spark plug
4) Inspecting the magnetic plug
Check the magnetic plug.
X X X X X 12–20–00
Inspecting
the magnetic
plug
5) Inspecting the oil filter
Remove oil filter from engine. Cut old
filter without producing any metal chips
and inspect following components for
wear and/or missing material
Filter mat:
Findings:
______________________________-
______
X 12–20–00
Inspection of
the oil filter
components
Filter cover:
Findings:
______________________________-
______
X 12–20–00
Inspecting of
the oil filter
components
Sealing lip (wear, cracks, missing
material):
Findings:
______________________________-
______
X 12–20–00
Inspecting of
the oil filter
components
Spring of bypass valve (small):
Findings:
______________________________-
______
X 12–20–00
Inspecting of
the oil filter
components
Effectivity: 915 i A Series
Edition 0/Rev. 0
05–20–00
Page 9
December 01 2017