EasyManua.ls Logo

Rotax 915 i A SERIES - Engine Performance and Fuel Consumption Data

Rotax 915 i A SERIES
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BRP-Rotax
MAINTENANCE MANUAL
Points of Inspection
Interval Operating hours Chapter
Reference
Signa-
ture
* no periodic maintenance (require-
ment after the first 25 hours of
operation)
25* 50 100 200 600 1000
13) Flushing the cooling system
Flushing the cooling system at massive
deposits on the expansion tank or radi-
ator cap and/or if the coolant manufac-
turer required an change interval.
when replacing the coolant 12–20–00
Flushing the
cooling
system
14) Engine cleaning
Engine cleaning. X X X X X 12–20–20
Engine
cleaning
15) Liquid level check
Verify liquid level, replenish as
necessary.
X X X X X 12–10–00
Fluid
capacities
16) Checking the pop-off valve
Check the pop-off valve for 700 mbar /
10.15 PSI low-pressure and its full
opening.
X
17) Engine test run
Observe the safety instructions!
Start the engine and run to operating
temperature.
Limits see Operators Manual 915 i A
Series
LANE check at _____ rpm engine
speed. Speed drop without LANE:
A (Off)___________rpm
B (Off)___________rpm
A/B (difference)________rpm
X X X X X 12–20–00
Test run of
engine
Returning engine to service
On the engine identified as per point 5, on the ___________________________the________hr.
Check at______hr. (TSN___, TSO___) was carried out according to recommendations of the engine manu-
facturer and was recorded in the Engine Log book.
Location, Date_______________________
Inspector___________________________
Aircraft mechanic_____________________
Certificate No.______________________
Effectivity: 915 i A Series
Edition 0/Rev. 0
05–20–00
Page 13
December 01 2017