NexU INSTALLATION MANUAL
71
see that we need to fill in a little more). During this time, the display integrated in the
device will show “top”, giving the possibility to extend the transaction.
Remote Display 1: Selection of a remote display (UView) to show the volume that is
being dispensed.
Remote Display 2: Selection of a second remote display (UView) to show the volume
that is being dispensed.
K Factor: You can change the calibration factor if it already known. In any case, it is
automatically changed when the calibration procedure is made in the UDat.
Max Quantity: Regulates the maximum quantity that is possible to dispense in one
transaction with previous preset value, including the first transaction and the topping
(additional filling up quantities).
Max Free of Service: Regulates the maximum quantity that is possible to dispense in
one transaction without previous preset value.
6.2.2.6 UCOUNT
Description: You can make a brief description of the UCount (i.e.: Quick Service
UCount)
Associated Tank: You have to associate the tank that is physically connected to the
device.
Display Quantity: Activates or deactivates the showing of the transaction on the display
integrated on the device. If this option is not chosen, moving arrows are showed on
the display during the transaction.
Pulsemeter Value: This parameter corresponds to the nominal value of the Pulse meter
that is connected to the UCount.
SV Aperture Delay: Regulates the time the solenoid valve takes to open after the
transaction confirmation.
Suspension Time: Regulates the pause time without receiving pulses from the pulse
generator. If the transaction is interrupted for a time longer than this value, the
transaction is counted as finished and the solenoid valve closes automatically.
Top Up Time: Regulates the waiting time after the initial transaction is completed,
making it possible to do an additional topping in the same transaction although the
preset quantity is achieved. After this stated time it is not possible to dispense an
additional quantity to the transaction and it is considered as completed.