Rev 3 (XXXX 2019)
NexU INSTALLATION MANUAL
72
For example, we have ordered 4 litres and after that these 4 litres have been
dispensed, this is the time available for making an additional topping to the original
transaction (for example another 0.2 litres, because even if we initially thought that the
crank case had 4 litres, when the 4 litres are dispensed and the dip stick is checked we
see that we need to fill in a little more). During this time, the display integrated in the
device will show “top”, giving the possibility to extend the transaction.
Remote Display 1: Selection of a remote display (UView) to show the volume that is
being dispensed.
Remote Display 2: Selection of a second remote display (UView) to show the volume
that is being dispensed.
K Factor: You can change the calibration factor if it already known. In any case, it is
automatically changed when the calibration procedure is made in the UDat.
Max Quantity: Regulates the maximum quantity that is possible to dispense in one
transaction with previous preset value, including the first transaction and the topping
(additional filling up quantities).
Max Free of Service: Regulates the maximum quantity that is possible to dispense in
one transaction without previous preset value.
6.2.2.7 UVIEW
Description: You can make a brief description of the UVision (i.e.: Quick Service UView)
6.2.2.8 UVISION
Description: You can make a brief description of the UVision (i.e.: Quick Service
UVision)
6.2.2.9 UVISION+
Description: You can make a brief description of the UVision (i.e.: Quick Service
UVision)
Address: Address of the device to which the UVision is connected to (UValve or
UMeter+).
Mode: Normal and Preset. (NOTE: The Preset mode can only be made when the
PRESET mode is chosen in the GENERAL Screen)