S84NX/S86NX Service Manual
142
Back to top 6 Troubleshooting
Error Number Type of Error Error Icon LED Buzzer
1079
Barcode Reading Error Light in red
Short
sound,
3 times
Message The setting value of checking start position is larger than the printed area.
To clear the display
Press the left select button (OFFLINE). The product changes to Offl ine mode
while keeping the print job.
Causes
A value larger than the loaded media length is specifi ed for checking start
position.
Countermeasures
• Check the layout for printing.
• Set a value smaller than the loaded media length for checking start position.
1080
Barcode Comparison Error Light in red
Short
sound,
3 times
Message Check printed barcodes.
To clear the display
Press the left select button (OFFLINE) or right select button (CANCEL).
• Press the left select button (OFFLINE) to change to Offl ine mode while
keeping the print job.
• Press the right select button (CANCEL) to cancel the print job and change
to Offl ine mode.
Causes The read result of the barcode does not match the print data.
Countermeasures
• Check the layout for printing.
• Check the barcode checker position and its settings.
1099
Confi g Warning Light in red
Short
sound,
3 times
Message Confi guration Initialization
To clear the display Press the left select button (OFFLINE).
Causes
The power was cut off in an inappropriate way, such as the power cord was
pulled out while the power was on.
Countermeasures
• Power off the product correctly.
• Reset the product in the Settings menu.