S84NX/S86NX Service Manual
141
Back to top 6 Troubleshooting
Error Number Type of Error Error Icon LED Buzzer
1076
Invalid command in NFC Light in red
Short
sound,
3 times
Message Failed to install settings from NFC.
To clear the display Press the left select button (OFFLINE).
Causes A command error occurs and the settings are not saved correctly.
Countermeasures
Check the command.
If the problem persists, replace the CONT PCB.
1077
Barcode Reader Connection
Error
Light in red
Short
sound,
3 times
Message Connect barcode reader.
To clear the display Connect the barcode checker, or press the left select button (OFFLINE).
Causes
• Could not check the connection of the barcode checker.
• Communication between the barcode checker and the product fails.
Countermeasures
• Check the barcode checker, and connect it correctly.
• If you do not use the barcode check function, disable the barcode check
mode.
1078
Barcode Reading Error Light in red
Short
sound,
3 times
Message Adjust attachment position of reader or confi rm reader settings.
To clear the display
Press the left select button (OFFLINE) or right select button (CANCEL).
• Press the left select button (OFFLINE) to change to Offl ine mode while
keeping the print job.
• Press the right select button (CANCEL) to cancel the print job and change
to Offl ine mode.
Causes Could not read the barcode correctly.
Countermeasures
• Check the layout for printing.
• Check the barcode checker position and its settings.