S84NX/S86NX Service Manual
47
Back to top
3 Checking and Performing Printer Adjustments
3
Select [START] (right select button)
>
[ ] (right select button).
Then, the sensor adjustment is automatically performed and shows the results.
[Tips]
When the printer shows a “Calibration failed” message, place the liner correctly and perform the auto-
calibration operation again.
The I-mark slice level is automatically adjusted by the following formula.
I-mark slice level = (High level – Low level) × 0.7 + Low level
Y
Adjusting the Gap Sensor Manually
4
Remove the labels from the liner and set the liner.
5
Select [Printing]
>
[Calibrate]
>
[GAP Levels].
6
Check and adjust the sensor low level and note
the low level value.
Check
Check that the sensor Level is less than 0.5 V
Adjustment
Adjust the sensor level by changing the value of the
Emit level.
If the sensor level does not fall below 0.5 V, adjust it by
changing the value of the Receive level.
7
With the screen as it is, set the media so that the label part is on the gap sensor.
[Tips]
For the sensor position, refer to step 2 of “Auto-calibration”.