3 Checking and Performing Printer Adjustments
8
Check and adjust the sensor high level and note
the high level value.
Check
Check that the sensor level satis es the following
conditions.
High level – Low level
1.0 V
The Low level is below 0.5 V.
Adjustment
Adjust the sensor level by changing the value of the
Emit level and Receive level.
9
Select [Calibrate]
>
[GAP Slice Level].
10
You can set the slice level arbitrarily.
Note
When the slice level is 0, the slice level is automatically
set.
Y
Adjusting the I-mark Sensor Manually
11
Place the label so that the I-mark does not cover the I-mark sensor.
Note For the sensor position, refer to step 2 of “Auto-calibration”.
12
Select [Calibrate]
>
[I-Mark Levels].
13
Check and adjust the sensor low level and
note the low level value.
Check
Check that the sensor level is less than 0.5 V.
Adjustment
Adjust the sensor level by changing the Send Gap
Level.
If you cannot set the sensor level to less than 0.5 V,
change the Receive Gap Level.