Back to top 4 Replacement
S84NX/S86NX Service Manual
83
9
Insert the BF stopper (
5
) back to the ribbon supply shaft (
7
).
Rotate the ribbon supply shaft (
7
) so that the pin stays horizontal. Hold the BF stopper (
5
)
as the concave inside stay horizontal as well and insert to the ribbon supply shaft (
7
).
Make sure that the concave of the BF stopper (
5
) engaged on the pin of the ribbon supply
shaft (
7
).
10
Orientate the BF stopper (
5
) such that the two straight ends of the BF spring (
6
) are
pointing downward and the metal projection is in between them.
7
5
Metal projection
Striaght ends of the BF spring
Pin
From here, assembling procedure
11
Perform the assembly with the reverse procedure from step 8.