SECTION IV
MAINTENANCE / SERVICE
Page 4-63Printed in U.S.A.
4.37 Line Power Pilot Lamp
Removal / Installation
A. Removal
(1) Perform steps 1 thru 7 of para 4.35A (removing
RFI filter).
(2) Disconnect two wires (1, Figure 4-66) from
terminals of line power pilot lamp (2).
(3) Remove line power pilot lamp (2) from bracket
assembly (3).
B. Installation
(1) Push line power pilot lamp (2) into bracket
assembly (3).
(2) Connect two wires (1) to terminals of line power
pilot lamp (2).
(3) Perform steps 3 thru 8 of para 4.35B (installing
RFI filter).
4.38 Plug Receptacle
Removal / Installation
A. Removal
(1) Perform steps 1 thru 7 of para 4.35A (removing
RFI filter).
(2) Tag and disconnect three wires (1, Figure 4-67)
from terminals of plug receptacle (2).
(3) Depress two locking tabs and remove plug
receptacle (2) from bracket assembly (3).
B. Installation
(1) Push plug receptacle (2) into bracket assembly
(3) until it "snaps" into place.
(2) Connect three wires (1) to terminals of plug
receptacle (2).
(3) Perform steps 3 thru 8 of para 4.35B (installing
RFI filter).
Figure 4-66. Line Power Pilot Lamp
Removal / Installation
HA5506-00
1
3
2
Figure 4-67. Plug Receptacle Removal / Installation
HA5507-00
1
3
2
LOCKING
TAB