4.23 Typical Base Mounted Control Valve
Solenoids Removal / Installation
A. Removal
DANGER
Table is very heavy. Use an assistant
to lay table onto its side. Failure to do
so could result in serious personal injury.
(1) Lay table onto its left side.
(2) Remove six screws (1, Figure 4-38) and main
cover (2) from base weldment (3).
(3) Remove two screws (4), two screws (5),
mounting bracket (6), two spacers (7), and
partially remove manifold assembly (8) from
base weldment (3).
(4) Remove nut (9), cap (10), o-ring (11), and
partially remove solenoid (12) from solenoid
mounting shaft (13).
Page 4-37Printed in U.S.A.
Figure 4-38. Control Valve Solenoids Removal / Installation
HA5486-00
1
2
3
4
5
7
6
9
11
8
10
13
12
14
15
16