SECTION IV
MAINTENANCE / SERVICE
(13) Secure motor pump (6) to base weldment (4)
with two mounting brackets (3), four screws
or
nuts (2), and four screws (1).
(14) Coat o-rings on fitting seals (12 and 16, Figure
4-44) and fitting connectors (11 and 15) with oil.
(15) Connect hose (17) to manifold of motor pump
(14) with fitting seal (16) and fitting connec-
tor (15).
(16) Connect tube assembly (13) to manifold of
motor pump (14) with fitting seal (12) and fitting
connector (11).
(17) Install manifold assembly (10) on base
weldment (5) and secure with two spacers (9),
mounting bracket (8), two screws (7), and two
screws (6).
(18) Install control box (4) on base weldment (5) and
secure with mounting bracket (3), two screws
(2), and two screws (1).
(19) Install main cover (7, Figure 4-43) on base
weldment (3) and secure with six screws (6).
(20) Connect four hot wires (4) to terminals of
batteries (5).
(21) Install battery cover (2) on base weldment (3)
and secure with five screws (1).
(22) Raise table to its upright position.
(23) Remove shipping plug from reservoir
(4,Figure 4-42).
(24) Add oil to reservoir (Refer to para 4.2).
(25) Screw breather cap (3) into reservoir (4).
(26) Install hole plug (1) in base weldment (2).
4.27 Pump Unit Removal / Installation
A. Removal
(1) Perform steps 1 thru 14 of para 4.26 A, Re-
moval.
(2) Place drain pan under shipping plug (See
Figure 4-47).
(3) Remove shipping plug from pump cover (1,
Figure 4-47) and allow all oil to drain into drain
pan.
(4) Remove four screws (2), lockwashers (3), pump
cover (1), and gasket (4) from manifold (5).
(5) Remove two screws (6), lockwashers (7), pump
unit (8), o-ring (9), and o-ring (10) from mani-
fold (5).
(6) Remove coupler (11) from motor shaft (12).
(7) Remove filter assembly (13) from tube assem-
bly (14). Discard filter assembly.
(8) Remove tube assembly (14) from pump
unit (8).
B. Installation
(1) Clean all metal components with degreasing
solution and allow to air dry.
NOTE
The side of the pump unit (8) which does not have
tube assembly (14) installed on it must have a plug
installed. If not, remove plug from old pump unit and
install in new pump unit.
(2) Install tube assembly (14, Figure 4-47 ) on
pump unit (8).
(3) Install filter assembly (13) on tube assem-
bly (14).
(4) Install coupler (11) on end of motor shaft (12).
(5) Coat o-rings (9 and 10) with oil.
(6) Install o-rings (9 and 10) on pump unit (8).
Page 4-45Printed in U.S.A.© Schaerer Mayfield USA, Inc. 2004