HB-37350-810-01-50F-EN PSC1-C-10 Installation manual V2.1.docx Page 169 of 189
Version: 50F
Example software specification
Monitoring V_rope in
relation to V_required
Monitoring of the
difference between main
drive speed and rope drive
for maximum value
Digital
incremental
encoder,
tacho generator
sheave
Monitoring using tested function SLS
+ SAC with comparison of speed
ranges / analogue value range =
comparison for diagnostics on the
speed acquisition
Shutdown 2-channel new (see
below)
Continuous
Reset:
Reset button
Backstop
Monitoring for return
Mechanical limit
switch 22S2
Digital
incremental
encoder
Monitoring using tested function,
direction monitoring SDI
NOT (auxiliary
contact 28K4 –
inspection
movement)
Reset:
Reset button
Stepwise shutdown 3
Activation of the safety
brake
Processing of SF in SafePLC2
SF 1.2
SF 1.3.2
SF 1.7
SF 1.8
Digital
incremental
encoder
Standstill monitoring using tested
function SOS
Controller disable
OR
Set service brake
SF 1.15/
Set safety brake
Digital
incremental
encoder,
Monitoring using tested function,
direction monitoring SDI
28K1 = FORWARD
28K2 = BACK