Page #94 background imageLoading...
Page #94 background image
Installation manual
HB-37350-810-01-50F-EN PSC1-C-10 Installation manual V2.1.docx Page 94 of 189
Version: 50F
4.3.5.3 Overview of achievable PL for digital safety outputs
Output
PSC1
Actuator /
external
shutdown
circuit
Category
accordin
g to EN
ISO
13849-1
DC
MTTF
d
actuat
or
Achie
vable
PL
accor
ding
to EN
ISO
13849-
1
Boundary condition
Fault
exclusion
Single-
channel
without
dynamic
output test
Qx
Q0_P, Q1_N,
Q2_P, Q3_N
IQQx
Single-channel
Contactor, valve,
brake etc.
without direct
feedback for
diagnostics
Cat. B
0 %
Medium
B
Contactor and
downstream actuators
suitably designed for
safety application
Single-channel
Contactor, valve,
brake etc. with
monitored,
positively driven
auxiliary contact
Cat. 2
60-
90
%
Depende
nt on
switching
frequenc
y
Medium
B
Signal output required
for warning if malfunction
detected
Contactor and
downstream actuators
suitably designed for
safety application
High
C
As before
D
As before
DC = 90% due to
adequately high test rate
in relation to the
application
Single-
channel
without
dynamic
output test
Qx
or
Single-
channel
Q0_P, Q1_N,
Q2_P, Q3_N
Dual-channel
Contactor, valve,
brake etc. with
direct feedback
for diagnostics in
at least one
channel
or
Actuator
operated with
single channel
with safety
function cat. 3
(e.g. STO)
Cat. 2
90
%
Monitorin
g only in
one
external
shutdown
circuit
Medium
c
Signal output required
for warning if malfunction
detected
Contactor and
downstream actuators
suitably designed for
safety application
Short-circuit
on external
operation
High
d
Single-
channel
without
dynamic
output test
IQQ00
..IQQ09
Dual-channel
Contactor, valve,
brake etc. with
direct feedback
for diagnostics in
at least one
channel
or
Actuator
operated with
single channel
with safety
function cat. 3
(e.g. STO)
Cat. 3
90
%
Monitorin
g only in
one
external
shutdown
circuit
Medium
or high
d
Contactor and
downstream actuators
suitably designed for
safety application
Short-circuit
on external
operation
Single-
channel with
dynamic
output test
IQQ00
..IQQ09
Dual-channel
Contactor, valve,
brake etc. with
direct feedback
for diagnostics in
both channels
or
Actuator with
safety function
cat. 4 (e.g. STO)
Cat. 4
99
%
Monitorin
g in both
external
shutdown
circuits
High
e
Contactor and
downstream actuators
suitably designed for
safety application
Monitoring
electromechanical
components by means of
positively driven
switches, position
monitoring on switching
valves etc.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the schmersal PSC1-C-10 Series and is the answer not in the manual?

schmersal PSC1-C-10 Series Specifications

General IconGeneral
Brandschmersal
ModelPSC1-C-10 Series
CategoryControl Unit
LanguageEnglish

Related product manuals