4.2.1.5 Overview of achievable PL for digital safety inputs
Type of
sensor /
input
element
Tests that can be
configured /
operative tests
Achieva
ble PL
accordi
ng to
EN ISO
13849-1
Fault exclusion for
input element
Condition for input
element
Input element proven in
operation
All faults on the input
element
Short-circuit on the
input/signal wire
MTTF
d
= high
Connection in the switch
cabinet or protected laying
All faults on the input
element
Short-circuit on the
input/signal wire
Input element corresponds at
least to Plr
Connection in the switch
cabinet or protected laying
Stuck
Short-circuit on the
input/signal wire
Predominantly high level
required (T
High
> 100 * T
Low
).
Positive opening,
MTTF
d
= high
Connection in the switch
cabinet or protected laying
All faults on the input
element
Short-circuit on the
input/signal wire
Input element corresponds at
least to Plr
Connection in the switch
cabinet or protected laying
MTTF
d
= high
Short-circuit between
input/signal wire
Connection in the switch
cabinet or protected laying
MTTF
d
= medium
Short-circuit between
input/signal wire (only
with same switching
elements = 2xNO or
2xNC)
Connection in the switch
cabinet or protected laying
MTTF
d
= high
Options:
X: Diagnostic measure activated
O: At least 1 diagnostic measure activated