EasyManuals Logo

schmersal PSC1-C-10 Series User Manual

schmersal PSC1-C-10 Series
189 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #179 background imageLoading...
Page #179 background image
Installation manual
HB-37350-810-01-50F-EN PSC1-C-10 Installation manual V2.1.docx Page 179 of 189
Version: 50F
Example:
Safety function:
Limitation of the max. travel speed of the running gear (FW) to 1.1 VMax
Monitoring of the maximum speed for < 1.1 VMax
"FW Max Speed OK", as long as FW Max Speed < 550 mm/s (bridged by "Lock error")
Monitoring "FW Max Speed" is continuously activated and triggers if a speed of
550 mm/s is exceeded.
Safety function:
Limitation of the max. travel speed of the running gear (FW) in the worker's area
Monitoring of the maximum speed for < 0.060 m/s
Safe Speed" monitoring is activated when the running gear is in the "WorkerArea",
"Setup" has not been activated and the maximum speed is exceeded.
SLS Safe Speed parameters:
60 mm/s, no other parameters