7
Project planning and startup with MOVITOOLS
®
MotionStudio
Communication via Ethernet
Manual – DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
53
Ethernet parameters for SMLP
The following table shows the communication parameters for SMLP:
No.
Ethernet para-
meter
Description Information
[2]
Timeout
Waiting time in ms that the
client waits for a reply from
the server after it has made
a request.
Default setting: 1000ms
If a delay of the commu-
nication causes failure, in-
crease the value.
[3]
Broadcast IP ad-
dress
IP address of the local net-
work segment within
which the device scan is
carried out.
In the default setting, the
device scan only retrieves
devices in the local network
segment.
[4]
IP address SMLP
server
IP address of the SMLP
server or of other devices
that are to be included in
the device scan but are
outside the local network
segment.
Enter the IP address of
devices that are to be in-
cluded in the device scan
but are outside the local
network segment.
If you are operating an in-
direct communication from
Ethernet to PROFIBUS,
enter the IP address of the
controller.
[6]
Excluded IP ad-
dress
IP addresses of devices
that should not be included
in the device scan.
Enter the IP address of
devices that should not be in-
cluded in the device scan.
This can be devices that are
not ready for communication
(e.g. because they have not
been started up yet).
Adding devices to the local network segment
During a device scan, the system recognizes only devices that are in the same local
network segment as the engineering PC. If you have devices that are outside the local
network segment, add the IP addresses of these devices to the list of SMLP servers.
Proceed as follows:
1. Open the "SMLP settings" tab [1](→252).
2. Select the address list of the SMLP server.
3. Open the "IP address of SMLP server" tab [5](→252).
4. To enter the IP address, click on the plus symbol[7].
5. Enter the IP address in the edit box [8]. Click [OK].
22900055/EN – 08/2016