Project planning and startup with MOVITOOLS
®
MotionStudio
Executing functions with the units
Manual – DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
60
Resetting IP address parameters
If you do not know the IP address parameters and there is no serial interface or
DBG60B keypad for reading the IP address, you can reset the IP address parameters
to the default values using the DIP switch 2
0
.
This action resets the DHR21B/41B option card to the following default values:
IP address: 192.168.10.4
Subnet mask: 255.255.255.0
Standard gateway: 192.168.10.4
DHCP / Startup Configuration: Saved IP parameters (DHCP is deactivated)
Proceed as follows:
1. Switch off the 24VDC supply voltage and the mains voltage.
2. On the DHR21B/41B option card, set DIP switch 2
0
to "1" (= right = ON).
3. Switch the DC24V supply voltage and the mains voltage back on.
ð The IP address parameters are reset.
7.6 Executing functions with the units
7.6.1 Reading or changing unit parameters
Proceed as follows:
1. Switch to the required view (project view or network view).
2. Select the connection mode:
If you want to read/change parameters directly on the unit, switch to online mode
by using the icon [1].
If you want to read/change parameters in the project, switch to offline mode by us-
ing the icon [2].
[1] [2]
18014399643939211
3. Select the unit you want to parameterize.
4. Choose the command [Startup]>[Parameter tree] from the context menu.
ð This opens the "Parameter tree" view on the right section of the screen.