10
Technical data and dimension drawings
General technical data
Manual – DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
75
10 Technical data and dimension drawings
10.1 General technical data
The general technical data listed in the following table applies to:
• DH.21B/41B option card installed in the inverter
• DH.21B/41B controller in the UOH11B/21B stand-alone housing
General technical data
Interference immunity complies with EN61800-3
Ambient temperature
• Installed in MOVIDRIVE
®
MDX61B:
– 0°Cto+60°C
(Derating at 40°Cto 60°C→System manual MOVIDRIVE
®
MDX60B/61B)
• Installed in MOVITRAC
®
B (AC230V; AC400/500V to 4kW):
– -10°Cto+60°C
(Derating at 40°Cto 60°C→System manual MOVITRAC
®
B)
• Installed in MOVITRAC
®
B (AC400/500V over 4kW):
– 0°Cto+60°C
(Derating at 40°Cto 60°C→System manual MOVITRAC
®
B)
• Installed in the MOVIAXIS
®
MXM master module:
– 0°Cto+45°C
• Compact controller:
– -10°Cto+60°C
Storage temperature -25°Cto+70°C
Climate class EN60721-3-3; class 3k3
Type of cooling Convection cooling
Degree of protection IP20
Operating mode Continuous operation, see MOVIDRIVE
®
MDX60B/61B, MOVITRAC
®
B,
MOVIAXIS
®
system manuals
Pollution class 2 according to IEC60664-1 (VDE0110-1)
Installation altitude max. 4000m (asl)
22900055/EN – 08/2016