7
Project planning and startup with MOVITOOLS
®
MotionStudio
Communication via Ethernet
Manual – DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
52
7.4.2 Configuring the communication channel via Ethernet
The devices use the device protocol from SEW‑EURODRIVE SMLP (Simple
MOVILINK
®
Protocol) that is directly transferred via TCP/IP.
Proceed as follows:
1. Establish the communication channel via Ethernet(→245).
2. Set the SMLP protocol parameters in the following window in the "SMLP settings"
tab[1](→253).
18328429835
[1] "SMLP settings" tab [5] "IP addresses of SMLP server" tab
[2] Timeout [6] "Excluded IP addresses" tab
[3] Broadcast IP address [7] Add IP address
[4] Broadcast scan duration [8] IP address edit box
22900055/EN – 08/2016