EasyManua.ls Logo

SEW-Eurodrive DH 41B Series - Configuring the Communication Channel Via Ethernet

SEW-Eurodrive DH 41B Series
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Project planning and startup with MOVITOOLS
®
MotionStudio
Communication via Ethernet
Manual – DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
52
7.4.2 Configuring the communication channel via Ethernet
The devices use the device protocol from SEW‑EURODRIVE SMLP (Simple
MOVILINK
®
Protocol) that is directly transferred via TCP/IP.
Proceed as follows:
1. Establish the communication channel via Ethernet(→245).
2. Set the SMLP protocol parameters in the following window in the "SMLP settings"
tab[1](→253).
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
18328429835
[1] "SMLP settings" tab [5] "IP addresses of SMLP server" tab
[2] Timeout [6] "Excluded IP addresses" tab
[3] Broadcast IP address [7] Add IP address
[4] Broadcast scan duration [8] IP address edit box